Managing Files and Attachments to SCIEX Now Support Cases Using Large File Exchange

SCIEX Now Large File Exchange enables simple upload and download of files or attachments to all kinds of SCIEX Now support cases.

11/28/2024   

How to fix common waste drain line issues on ExionLC AE and Shimadzu LC-40 systems

For the ExionLC AE and Shimadzu LC-40 systems, all waste liquid is collected in the drain port at the front of the instrument and discharged using the waste drain line. If this drain line is not installed correctly, this can cause a leak, or the system will show a leak sensor or gas sensor error.

11/01/2024   

MRM results table error in SCIEX OS software: Library not installed. There is no installed library database

When creating a new results table with multiple reaction monitoring (MRM) data in SCIEX OS software, an error message appears after selecting the Process button: “Library not installed; there is no installed library database.” If a library search is not required, users can prevent the error from appearing again by deselecting the Quantitation and targeted identification and/or the Non-targeted screening options in the Workflow tab in the open processing method.

10/26/2024    SCIEX OS

Diagnosing signal instability when processing data in Analyst®, MultiQuant™, or SCIEX OS software

Signal instability typically results in fluctuating responses from samples with the same level of analytes, causing significant variability in measured outcomes. Due to random fluctuations in peak area, signal instability could also affect linearity and recovery. If signal instability is observed while processing data in Analyst®, MultiQuant, or SCIEX OS software, it's possible to diagnose the source of signal instability by evaluating: 1) sample and material preparation, 2) LCMS method instability, and 3) instrument issues.

Why are scan windows longer than detection windows in a scheduled MRM method in Analyst® software?

When setting up a scheduled MRM (sMRM) method in Analyst® software, users must add the time for the detection window (in seconds). However, sometimes, the resulting scan window for some of the analytes is larger than what is set in the method. Here, the reason for this issue and ways to prevent it are explained.

10/26/2024    SCIEX OS | Analyst Software

Purpose of PTD files in project folders in Analyst® software

Files with the PTD (.ptd) extension are database event logs in Analyst® software located within the event log folders in the Analyst Data sub-projects. The event log folders where the PTD files are saved contain the same name as the quantitation methods or results tables from which the event logs are generated. Users can open these files with Notepad, but the information is used internally by the software and is not helpful for end-user purposes.

10/26/2024    Analyst Software

Errors when closing LC or MS methods in SCIEX OS software caused by file names with special characters

After changing an LC or MS method in SCIEX OS software, if a user attempts to close the method without saving, the software will throw either one of these errors: 1) System.Xml.Xmlexception : ')' is an unexpected token or 2) An error occurred while parsing entity name. To avoid these errors, users must rename their project and/or method and avoid using special characters (e.g., &, #, $) in project and method names.

10/26/2024    SCIEX OS

Setting a new reference (representative) sample for a processing method in SCIEX OS software

Each processing method created in the Analytics mode in SCIEX OS software has a reference sample that defines the components and is used to set the integration parameters. Users may need to change this sample to update retention time information or for other reasons.

10/25/2024    SCIEX OS

Turning off the Dynamic Window Extension when using the Scheduled MRM™ algorithm in Analyst® software

The Scheduled MRM™ algorithm is a feature in Analyst® software that includes a dynamic window extension option. This option allows the scan window to be automatically extended up to the duration of the scan window. Using this feature could result in lower dwell time for some analytes and inconsistent scan times between analytes, requiring it to be disabled.

10/25/2024    Analyst Software

Custom columns do not automatically appear in new results tables in SCIEX OS software

Custom columns for manually entering data in a results table will not appear automatically in a results table in SCIEX OS software, even if they were in the workspace layout from a previous results table. A custom column added using the More menu in the Analytics module will only be available in the results table to which it was added. It will not be saved in the quantitation method file (.qmethod) or the workspace layout file (.qlayout).

10/24/2024    SCIEX OS

Location of compound optimization data files (wiff2) generated in SCIEX OS software

After performing a guided optimization in SCIEX OS software, the raw data file (wiff2) is automatically stored in the SCIEX OS Data root directory in the TempData folder.

10/23/2024    SCIEX OS

Error in SCIEX OS software: A different user currently has another instance of SCIEX OS open

When launching SCIEX OS software, the error message “A different user currently has another instance of SCIEX OS open” is received, preventing users from accessing SCIEX OS software, even if no other users have accessed the software.

10/23/2024    SCIEX OS

Adding custom columns to a batch in SCIEX OS software

To add a custom column to a batch in SCIEX OS software, right-click within the batch area and select the Add Custom Column option.

10/23/2024    SCIEX OS

Using Metrics Tracker in SCIEX OS software 3.4 with a SCIEX 7500+ system

Metrics Tracker is a new workspace in SCIEX OS software 3.4 that monitors trends in essential performance criteria on the SCIEX 7500+ system. After activating a hardware profile, the Metrics Tracker tile should appear in the Configuration section of the SCIEX OS software's home page.

10/22/2024    SCIEX OS

Bio Tool Kit microapp cannot manually sequence peptide MS/MS data from EAD-derived fragments

The Bio Tool Kit microapp embedded in PeakView® or SCIEX OS software cannot perform de novo manual sequencing or MS/MS fragment matching for peptides fragmented using electron activated dissociation (EAD) on a ZenoTOF 7600 system. The MS/MS data obtained by EAD is too complex and fragment-rich, presenting the software with too many options for potential fragment ions; however, the Bio Tool Kit app can process MS/MS data acquired by CID (collision-induced dissociation).

Middle-down sMRM HR acquisiton method setup using EAD fragmentation on the ZenoTOF® 7600 system

This article describes the parameters for evaluating subunit proteins using electron-activated dissociation (EAD) fragmentation on the ZenoTOF® 7600 system. Specific values for a successful middle-down, high-resolution sMRM acquisition method using EAD fragmentation are provided. Choosing a low, medium, and high charge state of the protein envelope is critical to get the most diverse fragmentation.

10/21/2024    Academia Omics | Pharma CRO | SCIEX OS

Formula Finder returns NA/NA in Explorer mode in SCIEX OS software

In Explorer mode of SCIEX OS Software, Formula Finder's "Found" column will read NA/NA in the Found elemental compositions table when a ChemSpider license is installed.

10/17/2024    SCIEX OS

Creating a client license for SCIEX software supported by a concurrent license server

When setting up a concurrent license server for either Analyst® or SCIEX OS software, one of the final steps is to create and distribute the client license - the license installed on the PC where the SCIEX software is installed.

10/17/2024    SCIEX OS | Analyst Software

How can I restrict permissions for reporter templates?

It is often necessary that reporter templates are not altered—neither intentionally nor unintentionally. Therefore, it is important to restrict access to the template data files—this can be done at the Windows level in the file properties.

Adding compound names with square brackets causes LibraryView™ software error: Duplicate compound name in database

When attempting to add a compound name with square brackets to a library from the Analytics workspace in SCIEX OS software, the error "Duplicate compound name in database" appears. To resolve this issue, open LibraryView™ software and ensure the compound is deleted from the trash before adding the new compound under that name.

10/05/2024    SCIEX OS

Using the auto-processing feature in SCIEX OS software in the Batch workspace

Data under acquisition can be automatically processed and added to a results table on a sample-by-sample basis in the Batch workspace in SCIEX OS software. Entering a processing method and a results file name into the Batch workspace in Analytics triggers the auto-processing feature. Individual samples are processed into a results table that is progressively constructed over the course of data acquisition. The auto-processed samples can be added to an existing results table or an entirely new table.

10/05/2024    SCIEX OS

How to create decision rules in SCIEX OS software in the Batch workspace

Enabling decision rules in the Batch workpace allows SCIEX OS software to evaluate the acquired sample using flagging rules defined in an existing processing method. If the decision rule fails, it is possible to dictate the next action in the queue, such as sample re-injection.

10/05/2024    SCIEX OS

Setting up layouts in SCIEX OS software to customize the Analytics workspace

Layouts preserve the format and design of the Analytics workspace in SCIEX OS software. The Analytics workspace is customizable, and results table columns and panes can be organized according to the user's preference. Instead of reconfiguring the layout each time a new results table is created, users can save a layout to maintain the results table formatting for specific projects. Once saved, the layout can be set as the default, ensuring that a particular workspace is permanent and any new results table retains the features of previous results tables in that project.

10/04/2024    SCIEX OS

New calculated column functionality added to SCIEX OS software starting with version 3.3.1

Version 3.3.1 of SCIEX OS software includes many new calculated column functions that were not available in previous versions. Below is a description of these new functions and how to use them.

10/03/2024    SCIEX OS

Disable the User Account Control settings before installing Acquity driver for SCIEX OS software

To prevent driver installation issues, it is recommended that you disable the User Account Control (UAC) settings in Windows before installing the Acquity Driver that interfaces with SCIEX OS software.

09/30/2024    Software

How to use Bio Tool Kit for interpreting peptide MS/MS data acquired with CID and EAD fragmentation?

The Bio Tool Kit and its Peptide Fragments feature is tremendously helpful when trying to interpret MS/MS peptide data. This can be adjusted to either CID (collision-induced dissociation) or EAD (electron activated dissociation). A glycopeptide example for EAD and CID is described.

Processing oligonucleotides using Bio Tool Kit software

The Bio Tool Kit software can deconvolute oligonucleotides in negative mode using the Reconstruct Protein option. The Bio Tool Kit microApp is embedded in the PeakView™ or SCIEX OS software and requires an additional license to activate these features.

Eliminating license notifications in LibraryView™ and SCIEX OS software requires identical regional settings

A license notification screen appears when launching LibraryView due to a language setting mismatch between SCIEX OS and LibraryView™ software. Adjusting the regional language settings for both software packages will eliminate these license popup screens.

09/27/2024    SCIEX OS | LibraryView Software

Can I obtain statistics information for internal standards in SCIEX OS software 3.4?

In SCIEX OS software 3.4, users can generate statistics for internal standards samples. To display the Statistics pane for internal standards in a results table, highlight the section All Internal Standards in the Components and Groups tab, and then select the option Statistics pane in the Views drop-down menu to display statistics, such as mean, standard deviation, and percent CV for internal standards values (area, peak height, and retention time).

09/26/2024    Software

sMRM Calculator in Analyst® shows error 'unable to load method'

sMRM calculator does not work in mixed and integrated mode and displays error 'unable to load method. Check if the method is for the active hardware profile'.

09/26/2024    Analyst Software

Can the sample information in a data file be exported from SCIEX OS 3.4 software?

Users can now export sample information as a text file from the Explorer module in SCIEX OS 3.4 software. Open a data file, select the Show menu, and select Sample Information. Once the Sample Information pane is open, select the Export option and select Sample Information as Text.

09/26/2024    Software

Denoting a GPL result file as reviewed and approved in SCIEX OS software

GLP users need to be able to demonstrate that a results file has been reviewed and approved. A new workflow has been introduced in SCIEX OS software 3.4 to accommodate this requirement. Users can now mark the results file as reviewed or approved from the Results drop-down menu.

09/26/2024    Software

Printing sample information in SCIEX OS software creates an audit trail event

In Explore mode, SCIEX OS software allows users to display and print sample information for a data set. In previous versions, printing the sample information was not recorded in the audit trail. Now, with SCIEX OS software 3.4, an event is created in the audit trail record, allowing users to track the output of these records.

09/26/2024    Software

Can the order of the components in a results table be changed in SCIEX OS software?

Users can change the order of the components in a results table in SCIEX OS software by adding a new row and copying and pasting a row from elsewhere in the Components tab of a processing method.

09/26/2024    Software

The in Sciex OS exported .csv audit trial is empty.

It is possible to receive empty .csv files exported from Sciex OS audit trail, caused by missing one of the csvhelper depend dll, which is Microsoft.Bcl.HashCode.dll. The issue has been resolved in the Sciex OS version 3.4.

09/25/2024    SCIEX OS

How can I apply my settings from an existing processing method to samples with new or different components?

Sometimes it is needed to transfer 'generic' customized settings from an existing *.qmethod to a new application, like custom calculations, library search parameters or flagging rules. In this case new or different components need to be added to the existing method, which can only be done if a new reference sample is attached to the existing method.

09/25/2024    SCIEX OS

Using GETSTAT with unknown sample types in SCIEX OS software 3.4

GETSTAT received additional functionality in SCIEX OS software 3.4. Found in the Calculated Columns section of the processing method, the GETSTAT function can now pull in statistics for unknown samples; previously, GETSTAT only worked with QC and standard samples. The new GETSTAT functionality now permits averaging of the calculated concentrations for replicate unknown samples, among other functions.

09/24/2024    SCIEX OS

Adding a new ADC linker to Biologics Explorer software

There are two options for adding an antibody-drug conjugate (ADC) linker in Biologics Explorer software for use in intact protein and peptide mapping workflows: 1) as a custom modification using the Modification Editor or 2) as direct additions into the Conjugates tab in the Protein Mapping - Settings window.

09/20/2024    Academia Omics | Software

How to calculate statistic values of Unknowns in SCIEX OS v3.3.1

The statistics pane in SCIEX OS displays various statistic values for Standards, Quality Controls and other sample types. The values can be transferred to the results table and used for further calculations via the Custom Calculations Operator ‘GETSTAT’. But as the GETSTAT functions are available only when the Group by Concentration for Standards or Group by Concentration for QCs grouping options are selected, it was not possible to transfer the statistic values for Unknowns in the results table. With new custom calculation operator there is a workaround to calculate statistic values for duplicate injections.

09/19/2024    SCIEX OS

How to increase the virtual memory size with Win 10 PC

Windows sets the initial minimum size of the paging file equal to the amount of random access memory (RAM) installed on your computer, and the maximum size equal to three times the amount of RAM installed on your computer. If you see warnings at these recommended levels, then increase the minimum and maximum sizes. This procedure is applicable for PC with Windows 10. For PC with Windows 7 you can follow this procedure: https://sciex.com/support/knowledge-base-articles/low-virtual-memory-warning-1481143909352_en_us

09/12/2024    Software

How to Detect Acquisition Method Changes

To detect changes in an acquisition method in Analyst® or Sciex OS, the sample information of two injections can be compared via Microsoft Word to track changes e.g. between runs of separate days.

09/10/2024    SCIEX OS | Analyst Software

Change CAD Gas Settings from Simplified (Low, Medium, High) to Operator (0-12) in Analyst® Software

The default setting of CAD gas in Analyst® software is “Simplified” and only allows to adjust CAD gas in three steps (low, medium, high). Switching to “Operator” allows to use values from 0 to 12 which enables a more efficient optimization of this parameter for MS/MS and LIT experiments.

09/09/2024    Analyst Software

Is there Quantitative Default Data for Testing Purposes Available from SCIEX?

To test software functionality and familiarize with the quantitation workflow of SCIEX OS, SCIEX provides Triple Quad 7500 raw data and result tables with different evaluation approaches on the homepage for download. The data is stored in a full SCIEX OS project and can be used with SCIEX OS v3.1.6 and higher.

09/04/2024    SCIEX OS

Plate and Well Types for Waters™ Autosampler

Description of plate setup with common ANSI format plates and considerations for needle placement

09/04/2024   

Generating a Service Package in SCIEX OS Software from Version 3.4

To generate a service package in SCIEX OS software that contains the event logs, select Configuration, Service and Support, and Generate a Support Package.

09/04/2024    SCIEX OS

How to rename a computer without having to reinstall SCIEX OS ?

This article explains how to change the name of a PC without having to reinstall the SCIEX OS software.

08/30/2024    SCIEX OS

How does the SCIEX OS software calculate the IS Quality in the results table ?

This article explains how to interpret the value indicated by IS Quality and how SCIEX OS calculates this value.

08/29/2024    SCIEX OS

Configuring ChemSpider and its databases in SCIEX OS software Explorer mode

To use ChemSpider in the Explorer mode in SCIEX OS software, Formula Finder settings must be configured correctly. After selecting the Show Options icon in Formula Finder, a Formula Finder Settings screen appears. Users must select the ChemSpider Service options in the Dictionaries tab to see the compounds suggested by ChemSpider in the Formula Finder window of the Explorer module. `

08/22/2024    Pharma CRO | SCIEX OS

Error when adding samples to a results table in lower versions of SCIEX OS software

An error appears when adding samples to an existing results table in SCIEX OS software versions below 3.0: "Collection was modified; enumeration operation may not execute." This is a known bug for processing methods that use combined flagging rules, and the issue was resolved in version 3.0.

08/22/2024    SCIEX OS

Error when adding MS/MS spectra to a library within SCIEX OS software

When trying to add an MS/MS spectum to a compound in a library in SCIEX OS software, an error appears: System.ServiceModel.FaultException`1[System.ServiceModel.ExceptionDetail] : Object reference not set to an instance of an object. Adding MS/MS spectra to other compounds from the same results table does not generate this issue, which is caused by the inclusion of an apostrophe in the compound's name.

08/21/2024    SCIEX OS

How to change company name in the MultiQuant software audit trail report ?

MultiQuant software users who have a CFR license have the ability to view and print a report of the Audit trails associated with the software. This report automatically displays the company name. This article indicates how to change the company name that is displayed in this report.

08/02/2024    MultiQuant Software

How to perform quantification by standard additions with MultiQuant® software ?

The quantification of compounds by standard addition in MultiQuant® software requires the use of a query. This article explains how to use this query.

07/16/2024    MultiQuant Software

How to backup mass spectrum databases with LibraryView when it is impossible to export as an lbp file due to a software issue ?

Software issues may prevent libraries from being backed up in LibraryView. This can be problematic in cases where custom databases have been created and the LibraryView needs to be reinstalled since uninstalling this software deletes all the libraries it contains. It is therefore essential to be able to make backups of these libraries in all circumstances.

07/01/2024    LibraryView Software

Components mismatch error in SCIEX OS software is due to extra space in analyte name

If an extra space is added to the end of an analyte name in the Components column in the Batch workspace, an error message "Components Mismatch: 1 component in the selected processing method is not found in any selected batch samples" is generated in SCIEX OS software. Removing the extra space in the component name will allow the data to be processed.

06/28/2024    SCIEX OS

Calculated column functions in SCIEX OS software in the Analytics processing method

Calculated columns found in the Analytics processing method in SCIEX OS software allow for the automatic calculation of raw data using user-defined functions that are otherwise not available when processing data. This article lists all the functions available in all versions of SCIEX OS for calculated columns.

06/28/2024    SCIEX OS

Mastering ExionLC AE & Shimadzu LC 40 Plate Calibration

Discover how to calibrate autosampler plates by watching this step-by-step video guide. Proper needle alignment is critical for EXION AE and Shimadzu LC-40 autosamplers that are commonly used with SCIEX LC-MS systems to prevent a needle from striking the vial cap or missing the vial completely, causing a bent needle. Plate calibration – or plate teaching – is also essential when using a new sample plate for the first time with your autosampler or as part of routine LC maintenance.

06/18/2024   

Canned Calculation to check the ‘Sum of PFAS’ according to EU directive 2020-2184 using SCIEX OS Software

This article provides information on the SCIEX OS custom calculations required for evaluating PFAS data according to the EU directive 2020-2184. The guidance requires that 'Sum of PFASs', which means the sum of per- and polyfluoroalkyl substances considered a concern for water intended for human consumption, shall not be above 0.1 µg/l. These calculations were created to provide a ready-made solution for flagging outliers.

06/18/2024   

Importing a .txt or .csv file into a batch in SCIEX OS software

Users can import batch information into the Batch Workspace in SCIEX OS software using the Import from File option under the Open menu.

06/14/2024    Software

How to select exported and saved table settings for a quantitation table in Analyst® Software?

This article provides information on how exported and saved table settings can be selected for new results tables in Analyst® Software.

06/12/2024   

How to implement the Maximum Allowed Accuracy Variation for Quality Controls (%) and Standards (%) in Analyst® Software?

This article provides information on how to implement the Maximum Allowed Accuracy Variation for Quality Controls (QCs, %) and Standards (STDs, %) in Analyst® Software. This is possible within the Quantitation Wizard process.

06/12/2024   

How can I process MS1-level oligonucleotides in Molecule Profiler software?

Molecule Profiler software includes workflows for oligonucleotide impurity studies conducted on an MS1-level. To start using these workflows for oligonucleotide studies, launch the software and select Processing Parameters from the Workflow menu on the left panel.

Secure Network Account (SNA) - Recommended for Network Acquisition with SCIEX OS

This article explains what a Secure Network Account is, when to use it and how to set it up for use with SCIEX OS Software. This is valid for all SCIEX OS versions. It is highly recommended for all systems using Network Acquisition, but especially in Regulated Environments, where restrictions on user permissions are enforced.

06/03/2024    SCIEX OS

How to use a CTC PAL 3 within Analyst® software?

A short introduction on how to create a hardware profile including CTC PAL 3 in the Analyst® software, importing Scripts to the Analyst Device Driver Software, managing Racks and creating an Acquisition Method.

05/30/2024   

Restoring and using the script - Manually Integrate - in Analyst® software versions 1.7.2 and 1.7.3

The script - Manually Integrate - is missing in Analyst® software versions 1.7.2 and 1.7.3, although it was previously supported in versions 1.7 and 1.7.1. This articles describes how to restore the script to these later versions of Analyst software. Instructions are provided for integrating peaks of interest with the script that were missed or only partially integrated.

How to check that the heaters located in the source of the MS are working ?

This article describes the procedure to follow to check that the heaters located in the source (Turbo V ion source and IonDrive Turbo V ion source) of the mass spectrometer are working. This procedure describes the procedures for both, Analyst® software and SCIEX OS software.

Adding workflow templates to Biologics Explorer software without the template manager

Biological Explorer software uses workflow templates that are typically packaged into the software using a built-in template manager. If the template manager is not working, then templates can be added to the Biologics Explorer software by transferring them to a specific file path on the C drive: C:\ProgramData\SCIEX\BiologicsExplorer\templates.

05/29/2024    Academia Omics | Pharma CRO

Canned Calculation for ICH Guideline M10 – 3.2.3 Matrix Effect Available for SCIEX OS Software

This article provides information on the custom calculations required for processing data according to the guidance found in ICH guideline M10 – 3.2.3. The guidance requires that the matrix effect is evaluated by analysing at least 3 replicates of low and high QCs, each prepared using matrix from at least 6 different sources/lots. For each individual matrix sources/lots evaluated, the accuracy should be within ±15% of the nominal concentration and the precision (per cent coefficient of variation (%CV)) should not be greater than 15%. These calculations were created to provide a ready-made solution for flagging in case of detected matrix effects.

05/15/2024   

How to configure stacked injection in SCIEX OS or Analyst® with a Shimadz LC 40

SCIEX OS and Analyst® have a feature that allows you to control the injector of a Shimadz LC chain directly in the Sciex software using custom injection programs. This article describes how to write the program to perform stacked injection with LC 40.

05/03/2024    SCIEX OS | Analyst Software

Where to find Signal-to-Noise in SCIEX OS Explore mode

This article explains how you can manually evaluate the Signal-to-Noise within a chromatogram in the SCIEX OS Explore mode.

12/08/2023   

SCIEX Triple Quad™ 和 QTRAP™ 系统常见 LC 问题处理

在SCIEX Triple Quad和QTRAP系统上运行LC-MS方法时,LC系统的压力问题、保留时间变化和峰丢失是常见的问题。请参阅分步说明以解决这些常见问题。

12/08/2023   

Locating the Name of a Server or PC Using the Command Prompt Window

This article describes the DOS commands used to access the name of the server or PC.

05/14/2020    Academia Omics | Software

ZenoTOF 7600 系统的故障排查:调谐和校准

This is a known issue in the ProteinPilot™ software 5.0.2 and was resolved with a patch.

04/16/2020   

ZenoTOF 7600 系统的故障排查:运行中的校准不通过

This is a known issue in the ProteinPilot™ software 5.0.2 and was resolved with a patch.

04/16/2020   

岛津 LC-40 系统的常见症状及其可能原因

下表显示了岛津LC-40系统可能遇到的常见症状,并详细说明了可能原因和能够采取的纠正措施。

11/21/2023   

怎样在MultiQuant定量方法或结果表中改变参考样品,改变MRM通道设置保留时间和积分参数

这文章给出改变MultiQuant软件改变参考样品的指引

08/04/2022   

十個建議減少LC/MS系統汙染

日期:05/21/2021 僅提供研究使用

06/28/2021   

成为仪器“所有人”后能获得哪些权限?

注册和登录sciex.com.cn 用户名后,该仪器直接显示在账号中;能访问该仪器的所有支持案例(无论是哪位使用人创建的案例); 能够为该仪器在线提交新的支持请求;可以为该仪器命名或修改命名昵称;能够访问与该仪器相关的所有状态信息*;能够控制SCIEXNow Online用户列表,及仪器使用者对该仪器的访问权限...

03/30/2020   

如何成为仪器的线上“所有人”

成为仪器的线上“所有人”后能够通过SCIEXNow Online实现实验室仪器的线上管理。操作方法为,在登录状态下进入https://sciex.com.cn/support 。在出现的页面中点击SCIEXNow 仪表板中的“仪器”模块...

03/30/2020   

怎样转移SCIEX的软件至其他电脑上

This is a known issue in the ProteinPilot™ software 5.0.2 and was resolved with a patch.

01/28/2019   

MultiQuant™软件如何生成.CSV格式的报告?

在MultiQuant™软件打开一个结果表,File菜单栏下选择Create Report,可生成.csv格式的报告。

01/24/2019   

模拟模式(Sim Mode)下激活Analyst TF 1.7.1 的硬件配置

安装Chronologic Ndigo驱动可以让Analyst TF 1.7.1运行在模拟模式下。

11/01/2018   

在Analyst定量结果表中,怎样修改、保存和导出结果表设置

本文讲述如何修改(选择和调整可见纵列,改变有效数字和符号),保存并导出Analyst结果表

11/01/2018   

怎样把SCIEX软件接入到实验室信息管理系统(LIMS)或实验室电子记录系统(ELN)中

本文介绍了把SCIEX软件接入到实验室信息管理系统(LIMS)或实验室电子记录系统(ELN)的几个方法

11/01/2018   

如何从岛津CBM内部为VIERROR找到错误日志

本文介绍了如何从岛津CBM内部为VIERROR找到错误日志

11/01/2018   

MultiQuant® 软件怎么修正离子比率Fail

如果离子比率在MultiQuant软件结果表中被标记,经常意味着峰积分的方法不一致。

09/06/2018   

在Analyst里修改积分参数以排除峰拖尾面积

有的分析物可能会出现拖尾现象,其中一些会需要从整个峰积分中排除拖尾面积。在IntelliQuan窗口下修改noise percentage参数可以有帮助。

09/06/2018   

CTC自动进样器怎么增加自定义样品盘

如何配置CTC自动进样器以用于各种不同样品盘

08/15/2018   

MultiQuant™软件中的Queries储存在哪里?

MultiQuant™软件后query存放在C:\ProgramData\AB SCIEX\MultiQuant\Queries

08/15/2018   

PeakView®软件中SWATH Acquisition™ MicroApp的许可信息

在PeakView®软件Help菜单中看license信息时,SWATH™ acquisition microapp的license信息在plug-ins list里面,而不是在PeakView的License Report页面

08/15/2018   

从MultiQuant定量方法(.qmethod)中删除化合物

删除MultiQuant 软件中的化合物MRM,需重新打开定量方法,选中化合物并删除。

08/15/2018   

Data Explorer软件中有什么设置可以让我获得更好的质谱图?

本文介绍了在Data Explorer 4.11软件中提高谱图质量的几个方法

07/09/2018   

Multiquant 3.0升级到3.0.1 或 3.0.2

本文提供了从MultiQuant 3.0升级到MultiQuant 3.0.1和3.0.2的步骤。

03/22/2018   

MultiQuant软件新安装后运行时显示License不被支持

MultiQuant软件新安装后运行时显示License不被支持,这与安装时勾选Audit Trail / Security有关

12/11/2017   

Analyst回归方程

本文档总结了Analyst定量计算的线性方程

12/04/2017   

激活Markerview 1.2.1.1软件,需要激活码而不是License文件

安装了Markerview 1.2.1.1软件后,需要激活码而不是License文件。激活码可以通过email [email protected]来取得。

11/14/2017   

Triple Quad或QTRAP的仪器灵敏度降低,可能意味着需要优化检测器CEM参数

Triple Quad或QTRAP的仪器灵敏度降低,可能意味着需要优化检测器CEM参数

09/29/2017   

杀毒软件Symantec v12.x与Analyst等软件的数据收集产生冲突

杀毒软件有可能影响Analyst®,Analyst TF以及其他相关软件(例如DiscoveryQuant™, Cliquid®, LightSight®, Reporter以及 MultiQuant™ )的数据采集。本文将对如何防止杀毒软件和Analyst等软件产生冲突进行指导。

09/18/2017   

ProteinPilot™ 5.0.1软件和Windows 10兼容吗?

ProteinPilot™ 5.0.1软件和Windows 10兼容吗?不,它只在Windows 7, Service Pack 1, 64-bit下运行

09/11/2017   

MultiQuant™安装后无法运行

在成功安装MultiQuant™ 软件并且第一次启动软件时,license激活窗口没有显示,license文件无法安装。

06/21/2017   

在Windows 7下怎样保存应用与事件记录

Windows的事件记录包含SCIEX软件的重要信息。通过以下步骤保存事件记录以便SCIEX的支持团队进行分析。

06/15/2017   

关于软件的 IQ/OQ测试计划,我在哪里可以找到更多信息?

更多的关于软件认证的服务可以通过电邮[email protected]获取信息

06/09/2017   

浓度高于ULOQ怎么让MultiQuant™软件进行标记?

在MultiQuant™软件中,可以通过设置浓度上限计算值来标记计算浓度超过ULOQ的样品

06/08/2017   

怎样处理Analyst软件弹出的注册窗口

刚刚安装、还没有注册的Analyst软件弹出注册窗口。本文教你如何得到注册码。

05/31/2017   

对Analyst®软件推荐的计算机维护

为了使Analyst®软件流畅运行,有哪些计算机维护的方法?

05/26/2017   

MultiQuant™ 软件不能生产报告

由于安装了错误版本的Microsoft Office导致Create Report选项没有在MultiQuant软件中显示

05/17/2017   

Analyst 1.6.3中,进样序列(Batch)运行完毕但液相泵继续工作

如果进样序列已经运行完毕而液相泵却停不下来,这时需要调节Queue Options下面的Max Idle Time。

04/27/2017   

在Analyst中,怎样把普通MRM方法转换为Scheduled MRM方法?

想要把普通MRM方法转换为Scheduled MRM方法,需要在Analyst方法中更新保留时间。

04/25/2017   

怎样编辑query扩展文件名?

要编辑query文件的扩展名,需要rename文件名。

04/13/2017   

母离子扫描IDA实验能在SCIEX TripleTOF中实现吗?

SCIEX的TOF仪器,包括5600, 5600+, 6600, X500R, 以及X500B,都不能做母离子扫描IDA。

04/13/2017   

Analyst: 怎样增加队列中样品数目的最大值?

队列样品数目最大值可以在Queue Options菜单下修改Max. Num. Waiting Samples设置。

04/04/2017   

安捷伦Infiniti II高效液相色谱和SCIEX6500+系统

本文描述了当安捷伦Infiniti II高效液相色谱和SCIEX6500+系统在运行中发生联机问题时的解决方法。

03/24/2017   

重启电脑,高效液相色谱和质谱来解决通讯问题

重启电脑,高效液相色谱和质谱可以解决通讯问题

03/20/2017   

虚拟内存不足的警告

如果你收到关于虚拟内存不足的警告,你需要增加最小页面文件值。

12/07/2016   

ProteinPilot 软件 fraglet.exe CHEMICAL EXCEPTION的错误

ProteinPilot 软件 fraglet.exe CHEMICAL EXCEPTION的错误

12/07/2016   

如何备份与移动MasterView谱库

本文描述了如何备份与移动MasterView谱库

12/07/2016   

4700的数据能把t2d格式转换为mzxml吗?

4700的数据能把t2d格式转换为mzxml吗?

10/07/2016   

在Skyline中为Analyst创建方法时怎样避免无效的列表格式错误

描述无效的transition列表格式原因

10/07/2016   

Ekspert™ 400 液相系统 – 更换流动相

本文描述了如何为Ekspert™ 400 液相系统更换流动相

10/07/2016   

ProteinPilot 错误信息为“fraglet.exe not well-formed invalid token at line 1 and position 33112not wellformed invalid token at line 3 and position 71”

ProteinPilot 有以下错误信息 “fraglet.exe – not well-formed (invalid token) at line 1 and position 33112not well-formed (invalid token) at line 3 and position 71”

10/07/2016   

Eksigent Nano III离子源接头配件能否在UPLC反压下工作?

Eksigent Nano III离子源接头配件能否在UPLC反压下工作?

10/07/2016   

Analyst 软件进样序列编辑器中 Could not open the batch data DAB Server Error的错误

从文件向Analyst导入进样序列时,出现 Could not open the batch data DAB Server Error 错误

09/04/2016   

怎样打印PeakView中的XIC Manager列表

本文介绍了打印PeakView中的XIC Manager列表的方法

09/04/2016   

在MultiQuant结果表中怎么导出相关系数r

文章介绍了如何在MultiQuant结果表中导出相关系数r。此功能仅在MultiQuant 3.0.1 版本可用。

09/04/2016   

含有页脚的Reporter 3.0.1报告模板转换为Reporter 3.2时出错

Reporter 3.0.1报告模板转换为Reporter 3.2时出错

09/04/2016   

登录LibraryView软件失败

登录LibraryView软件失败

09/04/2016   

在Windows XP下寻找电脑识别码(Computer ID)

本文描述了如何用Windows XP的cmd来寻找电脑识别码,用于注册SCIEX软件

09/04/2016   

Analyst Projects下拉列表不是按照字母顺序排列

Anlayst Projects 下拉列表不是按照字母顺序排列

09/04/2016   

Mascot.dll脚本能在win 7 Analyst 1.6上工作吗

定义了关于运行这个脚本的问题和解决办法

07/08/2016   

ConfigUpdater.exe 不能升级仪器固件

Windows防火墙的拦截导致ConfigUpdater不能升级仪器固件

07/08/2016   

怎样设置Analyst®软件网络数据采集

出于数据备份和获取的需求及网络安全原因,网络数据采集非常有用。这里介绍怎样设置Analyst的网络数据采集。

07/08/2016   

色谱图不能在打印报告中显示

在生产含有色谱图的报告时,在大量图谱生成后图像关联不能被显示的问题

07/08/2016   

Chemoview 2.0.2生成Excel报告时出现下面错误信息Programmatic Access to Visual Basic Project is not trusted

当Chemoview 2.0.2生成excel报告时产出错误,信息为“Programmatic Access to Visual Basic Project is not trusted”

06/02/2016   

用Aglient液相,能否显示压力曲线

本文介绍了如何在安捷伦液相的硬件profile中激活压力曲线

06/02/2016   

如何查找Windows7系统所在区域

SCIEX的软件(除非在release notes里面说明)只能在系统区域为英语-美国(en-US)下运行。本文介绍了如何确认系统区域。

06/02/2016   

Cliquid错误:Retrieving the COM class factory for component with CLSID

Cliquid软件可以成功地运行样品但是无法处理他们,并且会在窗口下方报告错误:Retrieving the COM class factory for component with CLSID {36977493-A670-11Dc-8Dcc-00104BC5f89A}…

06/02/2016   

在Analyst软件中怎样创建安全设置记录

本文解释了在Analyst工作站中使用打印模式或PDF模式输出安全设置的方法

12/22/2015   

我如何对MultiQuant Queries进行调试

在写MultiQuant query的时候经常需要看到query的计算方法。当把MultiQuant query设置成调试(debug)模式你就可以看到excel生成的文件并可以对算法进行纠错。

12/22/2015   

ChemoView设置的导入与导出

ChemoView设置可以导出,以便备份与转移到其它计算机中。

12/22/2015   

如何将.wiff转换为NetCDF格式

本文解释了如何用Analyst软件自带的Translat.exe将.wiff转换为NetCDF格式

10/02/2015   

LibraryView 1.0 创建SQL时出现的 21467259 错误

安装LibraryView 1.0 时出现的 21467259 错误:Error -21467259: failed to create SQL database: LibraryView, error detail: Unknown Error

10/01/2015   

Analyst.exe Unable To Locate Component pt95FKn71.dll的错误

运行Analyst激活硬件Profile时,出现“Analyst.exe - Unable To Locate Component' with message body 'This application has failed to start because pt95Fkn71.dll was not found.  重新安装软件可以解决这个问题。

10/01/2015   

Windows 7系统中安装Multiquant 3.0.x,在步骤中出现.NET Framework 3.5 SP1之后安装失败

Windows 7系统中安装Multiquant 3.0.x,在步骤中出现.NET Framework 3.5 SP1之后安装失败

10/01/2015   

在Analyst软件定量时出现Unspecified error错误

在Analyst软件定量时出现Unspecified error错误

10/01/2015   

在Analyst中怎样改变回归方程的科学记数法

本文描述怎样在Analyst中怎样改变回归方程的科学记数法

10/01/2015   

MarkerView与Microsoft Office 2013出报告时出现This method or property is not available for reading的错误

Markerview 1.2.1 结合 Microsoft Office 2013 生产报告时产生This method or property is not available because this command is not available for reading错误解决方法

10/01/2015   

由于当前用户不在security database的原因导致不能运行Analyst软件

This is a known issue in the ProteinPilot™ software 5.0.2 and was resolved with a patch.

10/01/2015   

Windows 7环境中Analyst在Explore定量模式下停止工作而崩溃

Windows 7环境中Analyst 1.6.x停止工作并且显示“AB Sciex Analyst has stopped working” 错误指示。这个情况经常出现在鼠标箭头与色谱图上移动的时候。

10/01/2015   

在Analyst软件中怎样计算信噪比

本文介绍了如何在Analyst软件中的Explore或者Quantitate模式下计算信噪比

10/01/2015